Why it exists
ISO 26262 deals with faults. But an automated emergency braking system can also cause harm when it works exactly as designed — for example when it misinterprets a shadow as an obstacle. These are functional insufficiencies.
What SOTIF covers
- Triggering conditions: situations that lead to hazardous behaviour (glare, unusual objects).
- Known and unknown unsafe scenarios: reduce both through analysis, simulation and testing.
- Validation: argue that the residual risk is acceptable.
ISO/PAS 8800 extends this to AI: data quality, model development, training and monitoring in operation.
Best practices
- Combine scenario-based simulation with field data to discover unknown unsafe scenarios.
- Define the operational design domain precisely.
Common pitfalls
- Treating SOTIF as a testing activity only, without design measures.